Twin Circuit Chiller machine
Twin Circuit Chiller machine

Twin Circuit Chiller machine

Twin Circuit Chiller machine Specification

  • Refrigerating Capacity
  • 10 TR - 40 TR (depending on model)
  • Material
  • Powder-coated mild steel cabinet
  • Application
  • Industrial process cooling, plastic processing, HVAC
  • Air Flow
  • High-efficiency axial fans; approx. 5600 m/h
  • Motor
  • 3 HP (water pump motor); TEFC type
  • Condition
  • New
  • Type
  • Air cooled twin circuit chiller
  • Dimension (L*W*H)
  • 1840 x 820 x 1580 mm (typical for 20 TR)
  • Power Supply
  • Three phase, 50 Hz
  • Voltage
  • 41510 VAC
  • Cooling Type
  • Air cooled, dual refrigeration circuits for redundancy
  • Nozzle Material
  • Stainless steel
  • Cooling Coil Material
  • Copper with aluminum fins
  • Water Flowing Rate
  • 450 LPH - 1200 LPH (model dependent)
  • Water Pump Motor
  • Centrifugal, 3 HP
  • Noise Control
  • Low noise operation <72 dB(A)
  • Compressor
  • Twin circuit, hermetically sealed scroll-type compressors
  • Minimum Circulation Pressure
  • 2.5 kg/cm²
  • Control Panel
  • Microprocessor based digital control system
  • Condenser Type
  • Fin and tube type, air cooled
  • Expansion Valve Type
  • Thermostatic Expansion Valve
  • Number of Circuits
  • 2 fully independent refrigeration circuits
  • Evaporator Type
  • Shell & tube or PHE, model dependent
  • Working Temperature Range
  • 5°C to 25°C outlet water
  • Safety Features
  • High/low pressure cutout, overload protection, phase failure relay, anti-freeze protection
  • Caster Wheels
  • Provided for portability
  • Display
  • LCD display with temperature indicator
  • Water Tank Capacity
  • 150 Liters (integrated storage)
  • Refrigerant
  • R-407C/Eco-friendly refrigerant
 
 

About Twin Circuit Chiller machine

The offered Twin Circuit Chiller is widely acclaimed in the marketplace owing to its top-notch quality and long service life. This offered chiller is basically a device that is employed for cooling purpose. It is well-designed and assembled in our state of the art production division. Owing to its rugged construction and cutting-edge design, it functions optimally. Clients can approach us to purchase the Twin Circuit Chiller in various capacities and technical configurations as per their requirements. 


High-Efficiency Dual Circuit Design

The twin circuit refrigeration setup employs two fully independent scroll compressors, providing redundancy. This feature guarantees continuous operation even if one circuit requires maintenance, making it ideal for mission-critical applications. Each circuit uses the eco-friendly R-407C refrigerant to minimize environmental impact while maximizing cooling capacity.


User-Friendly Digital Control Panel

Equipped with a microprocessor-based digital control system, the chiller offers precise temperature regulation and monitoring. The intuitive LCD display shows real-time temperature and system parameters, ensuring operators can swiftly adapt to changing process requirements for greater efficiency.


Advanced Protective Features for Safety

The chiller incorporates high/low pressure cutouts, overload protection, anti-freeze modules, and a phase failure relay. These features collectively protect the system components, enhance longevity, and uphold operational reliability even during voltage fluctuations or other external stresses.

FAQs of Twin Circuit Chiller machine:


Q: How does the twin circuit system enhance operational reliability?

A: The twin circuit chiller is designed with two completely independent refrigeration circuits. This allows the unit to continue cooling processes even if one circuit is out of service for maintenance, ensuring uninterrupted operation and significantly improving system reliability.

Q: What industries and processes can benefit from using this chiller?

A: This chiller is ideal for industrial process cooling, plastic processing, HVAC applications, and other manufacturing operations requiring robust temperature control. Its high cooling capacity and integrated storage make it suitable for settings where stable temperatures are critical.

Q: When should I check or adjust the operating parameters?

A: Operating parameters should be checked during initial startup, routine maintenance checks, and whenever there is a change in process requirements. The microprocessor-based control panel with LCD display makes adjustments and monitoring straightforward.

Q: Where can this chiller be installed?

A: Owing to its portable caster wheels and compact design, the chiller is suitable for installation in a variety of industrial facilities, including factories, workshops, and production lines. It should be placed in well-ventilated areas to ensure efficient air cooling.

Q: What is the process for starting and operating the chiller?

A: To operate, ensure the unit is connected to a suitable three-phase power supply, fill the water tank, and power on via the digital control panel. The system will automatically manage temperature settings and display real-time data. Always consult the user manual before operation.

Q: What are the main benefits of the microprocessor-based digital control system?

A: The digital control system provides precise temperature regulation, automatic fault diagnostics, and operational logging. Its user-friendly interface enables fast adjustments, contributing to consistent cooling and energy efficiency.

Q: How does the chiller maintain low noise operation?

A: The unit employs high-efficiency axial fans and a specially designed structure to keep noise levels below 72 dB(A), making it suitable for environments where minimal noise is essential.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail